Anti-Static Steel Raised Floor

Designed for data centers and server rooms with stable load and electrostatic control.

Anti-Static Steel Raised Floor

Standard Size:600 × 600 × 35 mm

Panel Structure:Steel shell with cement-filled core

Surface Finish:HPL anti-static laminate

Installation System:Stringer system

Typical Applications:Data centers, server rooms, equipment rooms

Load Performance:Designed for heavy-duty equipment (details on request)

Designed for data centers and technical environments where load stability, electrostatic control, and long-term durability are required.


Typical Project Applications

• Data centers and server rooms
• Telecom and communication equipment rooms
• Control rooms and monitoring centers
• High-load technical and IT facilities

Key Engineering Advantages

• Cement-filled steel core provides high mechanical strength and load stability
• Anti-static HPL surface ensures controlled electrostatic discharge performance
• Compatible with standard stringer systems for flexible installation
• Stable panel structure suitable for long-term technical environments

System Structure & Materials

The raised access floor panel consists of a welded steel shell with a cement-filled core.
The top plate is manufactured from rigid cold-rolled steel, while the bottom plate uses deep-drawn steel for structural integrity.

The panel surface undergoes phosphating treatment followed by epoxy powder coating.
High-strength foamed cement is used as the core material, forming a stable and durable panel structure suitable for technical environments.

Load Performance & Compliance

Load performance values are based on standard testing conditions.
Detailed specifications can be provided according to project requirements.
System Performance Criteria
System Type       Static LoadsRolling Loads
PanelPanel SizeConcentrated
Load
Safety Factor
(min.2.0)
Ultimated load10 Passes10,000 Passes
 FS1000600x600x35mm
610x610x35mm
 454kg/1000lbsPass909kg/2000lbs368kg
800lbs
318kg
700lbs
  FS1250600x600x35mm
610x610x35mm
568kg/1250lbsPass1136kg/2500lbs454kg
1000lbs
368kg
800lbs
  FS1500600x600x35mm
610x610x35mm
681kg/1500lbsPass1363kg/3000lbs568kg
1250lbs
454kg
1000lbs
  • Design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. Design load is determined by taking the lesser value of ultimate load divided by two or the point at which permanent damage begins to occur (yield point).
  • Safety factor is the multiple of Design load to the Ultimate Load. International standards and bonaway recommend’ a minium of 2.
Installation & System Compatibility

The system is designed for installation with standard stringer and pedestal systems.
Panel height and layout can be adjusted according to underfloor service requirements.

The raised floor is compatible with common underfloor cable management and air distribution systems used in data centers and technical rooms.

Available Options & Customization

• Panel size and thickness options available
• Multiple surface finishes upon request
• Adjustable pedestal heights
• Project-based configuration support

Project Inquiry

For technical specifications, load calculations, or project-based quotations,please contact us with your application details.